SatPro Scatter-Free Sterile C-Arm Cover | Rothband
Interventional Accessories · Radiation Protection

SatPro Scatter-Free
Sterile C-Arm Cover

One sterile, single-use cover that drapes the C-arm and attenuates scatter at the same time. Lead-free shielding, fluid-resistant material and a fit that takes seconds, so your team spends less time setting up and receives less dose.

  • EO-sterilised
  • Lead-free composite
  • Single-use
  • Fits major C-arm brands
Sketch of an interventional C-arm system with the SatPro sterile cover fitted over the detector
29%average dose reduction
(phantom testing)
Why departments choose SatPro

Dose, hygiene and turnover, handled by one product

Under IRR17, every employer must keep staff exposure as low as reasonably practicable. SatPro adds a layer of protection right at the source of scatter, without adding steps to your set-up.

Less scatter for the team

Phantom testing shows an average 29% reduction in scattered dose, adding protection for operators, nurses and radiographers in the room.

Faster room turnover

Draping and shielding go on in one step and come off in one step. Nothing to wipe down, store or inspect between cases.

Lead-free and single-use

No reusable shields to decontaminate and no lead waste at disposal. Used covers go straight into the standard clinical waste stream.

Features & benefits

Built for busy theatres and labs

SatPro is designed to go on quickly, stay put during movement and keep fluids off expensive equipment, without getting in the way of imaging.

Lead-free composite shielding. Protective performance without the handling, storage or disposal issues of lead.

  • 1

    Effective scatter reduction

    Proven attenuation of scattered X-rays, with multiple shielding options available.

  • 2

    Sterile and single-use

    Supplied EO-sterilised, removing the cross-infection risk associated with reusable shields.

  • 3

    Fluid-resistant and tear-resistant

    Keeps blood, saline and contrast off the detector, and holds its integrity as the C-arm moves.

  • 4

    Quick, secure fit

    Lightweight, flexible construction with elasticated edges for a snug fit and fast set-up.

  • 5

    Fits major C-arm brands

    Designed for Siemens, GE, Philips, Canon and others, with no interference with image quality or controls.

Performance data

Scatter reduction across the kVp range

Scattered radiation reduction efficiency measured at 30 cm, for one and one-and-a-half layers of SatPro shielding.

Configuration60 kVp80 kVp100 kVp120 kVp
1 layer (30 cm) 57.9% 49.7% 44.4% 40.4%
1.5 layers (30 cm) 79.0% 72.9% 68.5% 65.1%

Manufacturer test data. In clinical phantom testing, SatPro gave an average dose reduction of 29% across typical procedure conditions.

Estimate your department's saving

Based on the 29% average dose reduction.

11.6 µSvsaved per day
2.67 mSvsaved per year

Indicative only. Actual reduction depends on geometry, technique factors and staff position. Your RPA can help interpret results for your department.

Clinical workflow

Five steps, no extra kit

  1. Open the sterile pack in the procedure room.

  2. Drape the cover over the C-arm detector or image intensifier.

  3. Secure with the elasticated edges or fixation points.

  4. Carry out the fluoroscopic procedure as normal.

  5. Dispose of the cover in line with local clinical waste policy.

Typical applications

Wherever a C-arm is in use

Operating theatres

Orthopaedic, vascular and general surgery

IR & cardiac labs

Interventional radiology and cardiology

Emergency departments

Rapid-access fluoroscopy

Pain clinics

Image-guided injections

Veterinary

Veterinary fluoroscopy, custom sizes available

FAQs

Common questions

Can't see your question here? Our team has clinical and radiation protection experience and is happy to help.

Ask Rothband
How much does SatPro reduce radiation dose?

Clinical phantom testing shows an average dose reduction of 29%. Scatter reduction efficiency ranges from 40% to 79% depending on kVp and the number of shielding layers.

Does the cover affect image quality?

No. The lead-free composite has no significant impact on diagnostic image quality.

Is it difficult to set up?

No. The all-in-one, lightweight design goes on in a single step and is secured with elasticated edges.

Which C-arms does it fit?

SatPro is designed for major brands including Siemens, GE, Philips and Canon. Tailored options are available for specific models. Tell us your equipment and we'll confirm fit.

Is the material lead-free?

Yes. There are no lead handling or hazardous waste concerns at disposal.

How does it save staff time?

By combining the sterile drape and the scatter shield, SatPro removes the separate step of positioning and cleaning secondary shielding.

Is it sterile?

Yes. Each cover is supplied EO-sterilised and ready for immediate use.

Can we trial it?

Yes. Contact Rothband to arrange a trial in your theatre, lab or practice.

Protect staff. Protect patients. Protect equipment.

Arrange a trial or request a quote for your trust, hospital or practice. Rothband has supplied radiation protection from Lancashire since 1911.

Request a quote or trial